Noise Floor Of Spectrum Analyzer

I know that long fft window lenghts or slow sweeps can pull out signal that is even bellow the noise floor becose coherent signals add 6db while incoherent noise adds only 3db thats means long fft or sweep will average the noise down more than the signal.
Noise floor of spectrum analyzer. However spectrum analyzers have a resolution bandwidth which is less than f s 2 this therefore lowers the analyzer noise floor by the process gain equal to 10 log 10 f s 2 bw where bw is the resolution noise bandwidth of the analyzer see figure 6 175. As the analyzer boots up you will see a message similar to figure 3 below prompting you to characterize the noise floor of the analyzer. Figure 9 for example depicts 50 mhz signal that appears to be shrouded by the analyzer s noise floor. Then the dut is connected and its signal captured and saved to trace 2.
If the instrument can display noise density it simply normalizes the power measurements to a 1hz bandwidth. 6 3 spectrum analyzer display over a 10 mhz frequency band centered on 1 ghz. Figure 3 characterize noise floor prompt 3. In signal theory the noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system where noise is defined as any signal other than the one being monitored.
With a spectrum analyzer what is a good method for determining the local noise floor in the lab area around the spectrum analyzer. If for example we wanted to determine the noise floor from 0 to 1 ghz would it be best to run a sweep using a full 1 ghz span or would it be better to pick various frequency ranges with smaller spans. The reference level is set to 70. The wider the bandwidth the more noise is measured for each data point.
I have another rf noob question how can spectrum analyser measure noise floor of dut. Measurement from a spectrum analyzer showing the noise floor. The noise floor of the spectrum analyzer is first averaged with the input terminated with these results saved to trace 1. Starting configuration for real time spectrum analysis on a high performance signal analyzer ideal for capturing intermittent and elusive signals 85 mhz real time and analysis bandwidth frequency mask trigger as short as 17 3 micro second.
This sensitivity to low level signals is affected by the analyzer settings. A spectrum analyzer s ability to measure low level signals is limited by the noise generated inside the spectrum analyzer. The displayed function is equivalent to. Trace math is then used for a power subtraction of the two traces with the results saved to trace 3.
Figure 4 characterize noise floor progress indicator. A progress indicator will appear on screen as shown in figure 4 below.