Obc Crossover Floors

The question is whether a cross over floor should be considered building common area or floor common area.
Obc crossover floors. Emergency access to floor areas 1 in a building more than 6 storeys in building height a except as permitted by sentence 3 doors providing access to floor areas from exit stairs shall not have locking devices to prevent entry into i any floor area designated as an area of refuge. A crossover floor or re entry floor as they are sometimes referred to are floors that allow you to exit one stairwell and proceed through a common corridor normally the elevator lobby to the other stairwell. They have completed hundreds of projects at our facility often large projects with the highest degree of quality. Exits and means of egress 1 except as permitted in sentences 2 and 3 every walkway or platform level shall be provided with no fewer than two exitsconforming to section 3 4.
2 an access to exit from an elevated platform level may be provided by means of open unenclosed stairs serving. An area above the highest cross over floor in a stairwell where cross over floors are provided or. Duct is less than 100 sq in duct is 24 ga no duct openings between corridor and adjacent spaces duct is above ceiling duct does not terminate at fire resistive wall duct has 16 ga 12 sleeve attached both sides with 1 5 angles secured to. You will be very pleased with this company.
The first floor of the structure is at grade level whereas the next accessible storey is located 64 62 m 212 ft above ground on the 25th floor. Protruding objects are permitted to extend below the minimum ceiling height required by section 1003 2 provided a minimum headroom of 80 inches 2032 mm shall be provided for any walking surface including walks corridors aisles and passageways. There are currently two fire separated exit stairs one that serves from grade level to the 26th floor and another that serves up to the 30th floor. 1 a fire schematic layout includes floor plans and cross section s indicating all fire resistance ratings and fire separations as required by the ontario building code.
A full floor tenant is not. They are normally 5 floors apart but this is not a perfect world so sometimes they may be less or more than the normal 5 floors. And shall include existing and proposed areas. Required to extend to the underside of floors or roof sheathing or all of the following.
In this specific situation the floor is required to be maintained open and free of objects in order to ensure that a person who needs to switch fire stair cases can freely go on the floor to the other staircase. 2 building area is a defined term under o b c. The building itself is a unique structure. The ontario building code emergency access to floor areas 3 4 6 18.
I have been a very satisfied customer of ob flooring for more than ten years. The ontario building code exits and means of egress 3 16 1 7.